TÜRKAK Temperature Calibration
Temperature calibration is applied to both portable and non-portable measurement devices, as well as large furnaces and coolers in the field.
World-class standard instruments are used in both the temperature calibration laboratory and on-site services to verify the performance of your temperature devices.
Temperature calibration is crucial for compliance with national and international standards. Regular calibration of equipment is of critical importance for energy efficiency, consistent, and high-quality production.
In addition to our laboratory calibration service, on-site calibration is performed for your immovable devices.
The calibration certificate you receive after calibration will explicitly report conditions outside tolerances, measurement traceability, accreditation, and information about the device’s status.
Application Area:
- Thermocouple Calibration
- Resistance Thermometer
- Incubator
- Oven (Paint Drying, Aging Oven, etc.)
- Furnace (Ash Furnace)
- Liquid Bath
- Climatic Chamber
- Sterilizer (Autoclave)
- Indicator Thermometer
- Cold Room, Refrigerator
Accreditation No AB-0276-K · TS EN ISO/IEC 17025:2017 · Revision 26.08.2025 / 01
Our accreditation scope
The table below is reproduced from the annex to our TÜRKAK accreditation certificate.
Every calibration in this scope can also be performed at your premises.
42 scope entries — scroll the table to see them all.
| Instrument calibrated | Measurement range | Conditions | Expanded measurement uncertainty (k=2) |
|---|---|---|---|
| Direnç TermometrelerPlatin Direnç Termometreler(PRT) | 0 °C | Buz Noktasında | 0,03 °C |
| Direnç TermometrelerPlatin Direnç Termometreler(PRT) | -25 °C ≤ T < 100 °C | Blok Kalibratörde | 0,44 °C |
| Direnç TermometrelerPlatin Direnç Termometreler(PRT) | 100 °C ≤ T ≤ 650 °C | Blok Kalibratörde | 0,66 °C |
| IsılçiftlerPlatin Bazlı Referans IsılçiftlerRSBPlatin/Pladyum (Pt/Pd)Altın/Platin (Au/Pt) | -25 °C ≤ T < 100 °C | Blok Kalibratörde | 1,24 °C |
| IsılçiftlerEndüstriyel IsılçiftlerTEKNJ | -25 °C ≤ T < 100 °C | Blok Kalibratörde | 0,65 °C |
| IsılçiftlerPlatin Bazlı Referans IsılçiftlerRSBPlatin/Pladyum (Pt/Pd)Altın/Platin (Au/Pt) | 100 °C ≤ T ≤ 650 °C | Blok Kalibratörde | 1,4 °C |
| IsılçiftlerPlatin Bazlı Referans IsılçiftlerRSBPlatin/Pladyum (Pt/Pd)Altın/Platin (Au/Pt) | 650 °C ≤ T ≤ 1100 °C | Blok Kalibratörde | 3,7 °C |
| IsılçiftlerEndüstriyel IsılçiftlerTEKNJ | 100 °C ≤ T ≤ 650 °C | Blok Kalibratörde | 0,9 °C |
| IsılçiftlerEndüstriyel IsılçiftlerTEKNJ | 650 °C ≤ T ≤ 1100 °C | Blok Kalibratörde | 3,6 °C |
| Göstergeli Sıcaklık ÖlçerlerDirenç | -25 °C ≤ T < 100 °C | Blok Kalibratörde | 0,28 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüT, J, K, N, E Tipi | -25 °C ≤ T < 100 °C | Blok Kalibratörde | 0,3 °C |
| Göstergeli Sıcaklık ÖlçerlerDirenç | 100 °C ≤ T ≤ 650 °C | Blok Kalibratörde | 0,48 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüT, J, K, N, E Tipi Base Metal | 100 °C ≤ T ≤ 650 °C | Blok Kalibratörde | 0,84 °C |
| Kontrollü Hacimler (SıcaklıkDağılımı)EtüvİnkübatörSoğuk Oda (derin dondurucu vb.)İklimlendirme KabiniSterilizatör (Otoklav)Sıvı BanyoIsıl İşlem Fırınları | -40 °C ≤ T ≤ 100 °C | Hacim İçerisinde Sıcaklık · Dağılımı | 0,88 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüT, J, K, N, E Tipi Base Metal | 650 °C ≤ T ≤ 1100 °C | Blok Kalibratörde | 3,6 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüAsil MetalR, S Tipi | -25 °C ≤ T < 100 °C | Blok Kalibratörde | 0,28 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüAsil MetalR, S Tipi | 100 °C ≤ T ≤ 650 °C | Blok Kalibratörde | 0,50 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüAsil MetalR, S Tipi | 650 °C ≤ T ≤ 1100 °C | Blok Kalibratörde | 3,5 °C |
| Göstergeli Sıcaklık ÖlçerlerIsılçift sensörüB Tipi | 650 °C ≤ T ≤ 1100 °C | Blok Kalibratörde | 3,2 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | 100°C ≤ T ≤ 1800 °C | B tipi | 1,21 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1000 °C | E tipi | 0,23 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1200 °C | J tipi | 0,28 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1370 °C | K tipi | 0,32 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1300 °C | N tipi | 0,36 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | 0 °C ≤ T ≤ 1700 °C | R tipi | 0,96 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | 0°C ≤ T ≤ 1700 °C | S tipi | 1,03 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 400 °C | T tipi | 0,34 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 850 °C | RTD tipi | 0,18 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -100°C ≤ T ≤ 650 °C | RTD1000 tipi | 0,17 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | 100°C ≤ T ≤ 1800 °C | B tipi | 1,21 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1000 °C | E tipi | 0,23 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1200 °C | J tipi | 0,28 °C |
| Kontrollü Hacimler (SıcaklıkDağılımı)Kül FırınıIsıl İşlem Fırınları | 600 °C ≤ T ≤ 1200 °C | Hacim İçerisinde Sıcaklık · Dağılımı | 3,92 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1370 °C | K tipi | 0,32 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 1300 °C | N tipi | 0,36 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | 0°C ≤ T ≤ 1700 °C | R tipi | 0,96 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | 0°C ≤ T ≤ 1700 °C | S tipi | 1,03 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 400 °C | T tipi | 0,34 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -200°C ≤ T ≤ 850 °C | RTD 100 tipi | 0,18 °C |
| Sıcaklık Göstergeleri veKalibratörleriSoğuk Eklem OFF | -100°C ≤ T ≤ 650 °C | RTD 1000 tipi | 0,17 °C |
| Kontrollü Hacimler (SıcaklıkDağılımı)Etüvİnkübatörİklimlendirme KabiniSterilizatör (Otoklav)Sıvı BanyoIsıl İşlem Fırınları | 0 °C ≤ T ≤ 300 °C | Hacim İçerisinde Sıcaklık · Dağılımı | 1,38 °C |
| Kontrollü Hacimler (SıcaklıkDağılımı)Sterilizatör (Otoklav)Kül FırınıIsıl İşlem Fırınları | 300 °C ≤ T ≤ 600 °C | Hacim İçerisinde Sıcaklık · Dağılımı | 2,36 °C |
Standards used: AMS2750 Pyrometry · AMS2750 Rehber · EURAMET cg-11 · Euramet cg-20 · Euramet/cg-08 · TS EN 60584-1 · TS EN 60751